Code CR 2500 Manuel d'utilisateur Page 49

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 62
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 48
C004386_07_CR2500_ User_Manual - 43
Save Settings
4.2 - Volume and Vibration Settings
Scan the following codes to set vibration mode:
Vibrate On / Beep On Vibrate On / Beep Off Vibrate Off / Beep On
Scan the following codes to set your reader’s volume:
Beep Off Beep Low Beep High (Default)
4.3 - Code Readability Index
The Readability Index provides a measurement of a specic symbol’s ease or difculty to be decoded by the CR2500. The
Readability Index is specic to the CR2500, and should not be confused with a verication quality measurement.
The Readability Index is a blend of information obtained from the internal operations of the decoding algorithm pertaining
to contrast, symbology construct, error detection, forward error correction (if applicable), and other symbology-specic
characteristics.
The Readability Index is a score on a scale of 01 (very poor) to 100 (very readable). Due to differences based on motion,
skew, reection, focus, and ambient lighting, the Readability Index on the same symbol may vary somewhat from read
to read. However, a poor contrast or damaged symbol will score lower than a high contrast undamaged symbol. The
Readability Index can be used as a quick check on the reliability of label generation or marking systems. When used in
conjunction with the CR2500 stand (or xed mount positioning) which xes the distance from the reader to the symbol, and
constant ambient light, the Readability Index provides a symbol quality assurance tool and check point for feedback to an
overall label or marking quality control system.
The Readability Index is enabled by rst reading a CodeXML® rule into the permanent CR2500 Memory:
Each time a data symbol is read, the index will be output, followed by a comma, (,) followed
by the decoded data. The reader will store the rule and reset, but will not output the
Readability Index until the Readability Index Output Enable code is read. The Reader will
continue to output the Readability Index upon every read until disabled, either by reset or by
reading the Readability Index Output Disable code.
Code Readability Index Rule: Readability Index Output Enable: Readability Index Output Disable: