Code Reader 1200 Manuel d'installation Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 176
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
INSTALLATION
15
2
Input
There is an input available on the TC1200-0000 Scan Engine relative to the External Trigger
used to signal the reading phase for On Line Operating Mode. The pins are indicated in
Table 1. This input is optocoupled, polarity insensitive and can be drive
n by both an NPN or
PNP type command. The connections are indicated in the following diagrams:
TC1200
EXTERNAL TRIGGER
ext 30 Vdc max.
7
8
Signal
V
V
CC
~
~
+-
EXT TRIG A
EXT TRIG B
J2
Figure 14 - Input NPN Command Using External Power
TC1200
EXTERNAL TRIGGER
V
ext 30 Vdc max.
7
8
V
CC
~
~
+-
V
Signal
EXT TRIG A
EXT TRIG B
J2
Figure 15 - Input PNP Command Using External Power
TC1200 EXTERNAL TRIGGER
7
8
Signal
V
CC
~
~
+
-
EXT TRIG A
EXT TRIG B
J2
10
GND
V
Vcc (5 Vdc)
9
J1
Ground
Figure 15 - Input NPN Command Using TC1200 Power
TC1200 EXTERNAL TRIGGER
7
8
Signal
V
CC
~
~
+
-
EXT TRIG A
EXT TRIG B
J2
10
GND
VVcc (5 Vdc)
9
J1
Ground
Figure 16 - Input PNP Command Using TC1200 Power
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 175 176

Commentaires sur ces manuels

Pas de commentaire