TC1200 REFERENCE MANUAL
30
3
POWER SAVE
Description Parameter Value
Sleep Mode Timeout Disable SLTO 00
10 seconds 01
30 seconds 02
1 minute 03
5 minutes 04
10 minutes 05
CODE SELECTION
Description Parameter Value
Positive/Negative Background Positive CGRD 00
Negative 01
Both 02
UPC-A
UPC-A Disable ABEN 00
Enable 01
Check Character Tx Disable ABCT 00
Enable 01
Expand to EAN-13 Disable AB3B 00
Enable 01
Number System Tx Disable ABNS 00
Enable 01
Minimum Reads One Read ABMR 01
Two Reads 02
Three Reads 03
Four Reads 04
Coupon Control Allow all coupon barcodes to be decoded CPCL 00
Enable only UPC-A coupon decoding 01
Enable only GS1 Databar coupon decoding 02
UPC-E
UPC-E Disable EBEN 00
Enable 01
Check Character Tx Disable EBCT 00
Enable 01
Expand to UPC-A Disable EBAB 00
Enable 01
Expand to EAN-13 Disable EB3B 00
Enable 01
Number System Tx Disable EBNS 00
Enable 01
Minimum Reads One Read EBMR 01
Two Reads 02
Three Reads 03
Four Reads 04
EAN-13
EAN-13 Disable 3BEN 00
Enable 01
Check Character Tx Disable 3BCT 00
Enable 01
ISBN Conversion Disable 3BIS 00
Enable 01
ISSN Conversion Disable 3BIN 00
Enable 01
Flag 1 Character Disable 3BF1 00
Enable 01
Minimum Reads One Read 3BMR 01
Two Reads 02
Three Reads 03
Four Reads 04
Coupon Control Allow all coupon barcodes to be decoded CPCL 00
Enable only UPC-A coupon decoding 01
Enable only GS1 Databar coupon decoding 02