10/29/2014
Page 33 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Decoder HD field (FOI 0)
Width
Valid Range: 1 to 640 pixels
Decoder uses only the specified pixel width in the HD field (FOI 0).
See section 8.2
Note: The High Density field (FOI 0) does not exist on the CR900FD.
Decoder HD field (FOI 0)
Height
Valid Range: 1 to 960 pixels
Decoder uses only the specified pixel height in the HD field (FOI 0).
See section 8.2
Note: The High Density field (FOI 0) does not exist on the CR900FD.
1: Send “r” packet on no-read (See “r” packet in Section 5.2)
0x100xx: post event on no-read, where the lower 8 bits specify the
event number. For example, 0x10009 to post Event 0x09.
Also see register 39 for a list of events.
Valid Range: 0 to 7FFFFFFF Milliseconds
Also see registers: 26, A7, 1F1
1: Enabled
Note: Enables and disables all UPC and EAN codes (UPC-A, UPC-E,
EAN-13, EAN-8)
Also see registers: 4D, 4E, 74
Code 32 is also known as Italian Pharmacode. It uses the same
encoding as Code 39 and can be decoded as Code 39 with
unintended data when Code 32 is not enabled. It is not necessary
to enable Code 39 to enable Code 32.
Also see register: 70