Vue de la page 1
Repair Parts and Maintenance Guide
31
Manual
Flushometers
The information contained in this document is subject to change without notice.
Crown
®
Flushometer
Crown
®
II (Obsolete)
Repair Parts and Maintenance Guide
IMPORTANT: The CROWN
®
flushometer is engineered for quiet operation.
Excessive water flow creates noise, while too little water flow may not satisfy
the needs of the fixture. Proper adjustment is made when plumbing fixture
is cleansed after each flush without splashing water out from the lip AND a
quiet flushing cycle is achieved.
Never open control stop to where the flow from the valve exceeds the flow
capability of the fixture. In the event of a valve failure, the fixture must be
able to accommodate a continuous flow from the valve.
ATTENTION INSTALLERS: With the exception of the control stop inlet,
DO NOT USE pipe sealant or plumbing grease on any valve component
or coupling! To protect the chrome or special finish of Sloan flushometers,
DO NOT USE toothed tools to install or service these valves. Use our
A-50 Super Wrench or other smooth-jawed wrench to secure couplings.
Regulations for low consumption fixtures (1.6 gpf/6.0 Lpf closets and
1.0 gpf/3.8 Lpf urinals) prohibit use of higher flush volumes.
1. Valve DOES NOT function.
A. Control stop or main valve is closed. Open control stop or main valve.
B. Handle assembly is worn. Install Sloan handle repair kit, or replace
handle.
C. Relief valve is worn and sticking in UP position. Replace piston.
2. Insufficient volume of water to adequately siphon fixture.
A. Control stop not open enough. Adjust control stop for desired delivery
of water.
B. Urinal piston parts inside a closet valve. Replace piston parts with
proper closet piston.
C. Low consumption valve installed on a non-low consumption fixture.
Replace with proper flushometer. Crown
®
flushometers are not
available with flush volume higher than 1.6 gpf/6.0 Lpf.
D. Inadequate volume or pressure at supply. Increase water pressure or
supply (flow) to valve. Consult factory for assistance.
3. Length of flush too short (short flushing) or valve closes off
immediately.
A. Piston assembly is not hand-tight. Screw the assembly hand-tight.
B. Enlarged bypass orifice from corrosion or damage. Install NEW inside
parts kit to correct problem and update flushometer.
C. Urinal piston in closet flushometer. Replace piston with proper closet
piston.
D. Low consumption piston installed in non-low consumption fixture.
Replace with proper flushometer. Crown
®
flushometers are not
available with flush volume higher than 1.6 gpf (6.0 Lpf).
E. Handle assembly worn. Install Sloan handle repair kit.
4. Length of flush too long (long flushing) or fails to close off.
A. Piston is not seating properly or bypass orifice is clogged because of
foreign material, or bypass orifice is clogged by an invisible gelatinous
film from “over-treated” water. Disassemble the working parts and
wash thoroughly. NOTE: Size of the orifice in the bypass is of utmost
importance for the proper metering of water into the upper chamber
of the valve. DO NOT enlarge or damage this orifice. Replace piston if
cleaning does not correct problem.
B. Line pressure has dropped and is not sufficient to force relief valve to
seat. Shut off all control stops until pressure has been restored, then
open them again.
C. Main seat is fouled with debris or is worn. Clean or replace main seat.
5. Leaking at handle assembly.
A. The B-85 seal may have deteriorated. Install new B-85 seal.
NOTE: The B-85 seal will easily slide onto the bushing if it is wet.
B. Handle gasket has been omitted. Install A-31 handle gasket or Sloan
handle repair kit.
C. Valve handle bushing is worn. Install Sloan handle repair kit.
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to
clean flushometers that may dull the luster and attack the chrome or special
decorative finishes. Use ONLY mild soap and water, then wipe dry with
clean cloth or towel.
While cleaning the bathroom tile, the flushometer should be protected from
any splattering of cleaner. Acids and cleaning fluids will discolor or remove
chrome plating.
TROUBLESHOOTING GUIDE
COVER
BODY
HANDLE
TRIM RING
HANDLE ASSEMBLY
FLUSH CONNECTION
(VACUUM BREAKER)
SPUD COUPLING
STOP COUPLING
CONTROL
STOP
SUPPLY
FLANGE
OUTLET
COUPLING
SPUD FLANGE
TAILPIECE
CROWN
®
II
SHOWN
COVER
TRIM RING
COVER
BODY
HANDLE
COUPLING
HANDLE ASSEMBLY
FLUSH CONNECTION
(VACUUM BREAKER)
SPUD COUPLING
STOP COUPLING
CONTROL
STOP
SUPPLY
FLANGE
OUTLET
COUPLING
SPUD FLANGE
TAILPIECE
CROWN
®
SHOWN
COVER
TRIM RING
OBSOLETE
Manual
Flushometers
When assistance is required,
please contact Sloan Technical
Support at: 1-888-SLOAN-14
(1-888-756-2614).
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
Piston
Identification
Chart
Water Closet Urinal
CR-1004-A CR-1011-A CR-1005-A CR-1006-A CR-1015-A CR-1014-A
3332003 3332013 3332004 3332004 3332017 3332016
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
Cap Color
Green Deep Purple Yellow Red Burgundy Pink
Piston Color
Green Green Clear Clear Burgundy Burgundy
Barrel
Large Ribs Large Ribs Small Ribs Small Ribs
Seat Color
Green Green Black Black Burgundy Burgundy
Grooves
2 0 1 3 1 3
1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf) 0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf) 0.125 gpf (0.5 Lpf)
Cap Color
Barrel (Large Ribs
or Small Ribs)
Piston
Color
Stem
Grooves
Vue de la page 1
1 2

Commentaires sur ces manuels

Pas de commentaire